High Quality 60V 10A 600W Switching Power Supply from China Suppliers and Factory – Low Ripple, High Efficiency
HX Features
Efficiency
It boasts high energy conversion efficiency, reducing power loss and ensuring maximum output for your devices.
Safety
Equipped with advanced safety features such as over-voltage, over-current, and short-circuit protection, it safeguards your equipment from potential damage.
Stability
The unit maintains a stable output voltage and current, ensuring consistent performance even under varying loads.
Reliability
Built with high-quality components, this power supply is designed for long-lasting durability and minimal maintenance.
Flexibility
Its compact design and versatile input voltage range make it suitable for various applications and easy integration into existing systems.
Certifications
The power supply meets international safety standards, ensuring compliance with regulations and providing peace of mind.
HX Specifications
| MODEL | HX-600-12 | HX-600-60 | |
| OUTPUT | DC voltage | 12V | 60V |
| Rated current | 50A | 10A | |
| Current range | 0-50A | 0-10A | |
| Rated power | 600W | 600W | |
| Ripple & noise | <120mVp-p | <450mVp-p | |
| Voltage adj range | ±10% | ±10% | |
| Voltage tolerance | ±1% | ±1% | |
| Line regulation | ±0.5% | ±0.5% | |
| Load regulation | ±0.5% | ±0.5% | |
| Setup, rise time | 200ms, 100ms | ||
| Hold up time | 20ms | ||
| INPUT | Voltage range | 90-132VAC / 180-264VAC Selected by switch | |
| Frequency range | 47-63Hz | ||
| AC current | 4.5A/115VAC 2.5A/230VAC | ||
| Inrush current | 25A/115VAC 50A/230VAC | ||
| Efficiency | 82% | 86% | |
| Leakage current | <3.5mA/240VAC | ||
| PROTECTION | Overload | 105-125% rated output power | |
| Over voltage | 115%-150% of voltage | ||
| Protection type | Shut down o/p voltage, re-power on to recover | ||
| Over temperature | -10°C ~ +60°C | ||
| Protection type (temp) | Shut down o/p voltage, recover automatically after temperature goes down | ||
| ENVIRONMENT | Working temp | 80°C±5°C | |
| Working humidity | 20%~90%RH non-condensing | ||
| Storage temp | -10°C ~ +60°C | ||
| Storage humidity | 10%~90%RH | ||
| TEMP coefficient | ±0.05%/°C (0-50°C) | ||
| SAFETY | Safety standards | Compliance to EN55022:2006+A1:2007; EN55024; EN 60950; EN61000-3-2:2006+A1:2009+A2:2009; EN61000-3-3:2008 | |
| Withstand voltage | I/P-O/P: 1500VAC, I/P-FG: 1500VAC, O/P-FG: 500VAC | ||
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG: 100MΩ | ||
| OTHERS | MTBF | 197K hrs min. MIL-HDBK-217F (25°C) | |
| Dimension | 215*115*50mm (L*W*H) | ||
| Packing | 0.93kg/pc, 10pcs/ctn | ||
| NOTE | 1. All parameters NOT specially mentioned are measured at normal input, rated load and 25 °C of ambient temperature. | ||
| 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||
| 3. Tolerance: includes set up tolerance, line regulation and load regulation. | |||
| 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | |||
HX Product Size
HX Workshop Production Line
HX Product Application