China NDR-120-24 Din Rail Switching Power Supply 24V 120W - Reliable Suppliers & Factory Solutions
Features
- Universal AC input / full range: 90-264V
- Short circuit / Overload / over Voltage / over temperature Protection
- LED indicator for power on
- Cooling by free air convection
- Soft-start current, decrease AC Inrush current
- Can be installed on DIN rail: TS-35/7.5 or TS-35/15
- Installed with EMI filter, minimum wave
- Small size & light weight
- 3 years warranty
Specifications
| Category | Parameters | NDR-120-12 | NDR-120-24 | NDR-120-48 |
|---|---|---|---|---|
| Output | DC voltage | 12V | 24V | 48V |
| Rated current | 10A | 5A | 2.5A | |
| Current range | 0~10A | 0~5A | 0~2.5A | |
| Rated power | 120W | 120W | 120W | |
| Ripple and noise (maximum) | 100mVp-p | 120mVp-p | 150mVp-p | |
| Voltage adjustment range | 12~14V | 24~28V | 48~55V | |
| Voltage accuracy | ±2.0% | ±1.0% | ±1.0% | |
| Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | |
| Load adjustment rate | ±1.0% | ±1.0% | ±1.0% | |
| Start and rise time | 1200ms,60ms/230VAC 2500ms,60ms/115VAC(full load) | |||
| Hold time (Typ.) | 16ms/230VAC 10ms/115VAC(full load) | |||
| Input | Voltage range | 90-264VAC 127-370VDC [DC input can be achieved by connecting AC/L (+), AC/N (-)] | ||
| Frequency range | 47~63Hz | |||
| Efficiency (Typ.) | 85.50% | 88% | 89% | |
| AC current (Typ.) | 2.25A/115VAC 1.3A/230VAC | |||
| Surge current (Typ.) | 20A/115VAC 35A/230VAC | |||
| Leakage current | <1mA/240VAC | |||
| Protection | Overload | 105%~130% of rated output power | ||
| Protection mode | Constant current mode, abnormal load bar | |||
| Overvoltage | 14~17V | 29~33V | 56~65V | |
| Protection mode (OV) | Turn off output, normal output can be restored after power restart | |||
| Over temperature | Turn off output, normal output can be restored after power restart | |||
| Environment | Working temperature | -20~+70℃ | ||
| Working humidity | 20~95%RH, non-condensing | |||
| Storage temp. & humidity | -40~+85℃, 10~95%RH | |||
| Temperature coefficient | ±0.03%/℃(0~50℃) | |||
| Vibration resistance | Component: 10~500Hz, 2G 10 minutes/cycle, X, Y, Z each for 60 minutes; Installation: Compliant with IEC60068-2-6 | |||
| Safety & EMC | Safety regulations | UL508, EAC TP TC 004, TUV EN62368-1 certification passed; (Meets EN60204-1) | ||
| Voltage resistance | I/P-O/P: 3KVAC, I/P-FG: 2.0KVAC, O/P-FG: 0.5KVAC | |||
| Insulation impedance | I/P-O/P, I/P-FG, O/P-FG: >100M Ohms/500VDC/25℃/70% RH | |||
| EMC emission | Compliant with EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2, -3, EAC TP TC 020 | |||
| EMC immunity | Complies with EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, A-grade heavy industry standard EAC TP TC 020 | |||
| Other | MTBF | ≥456.3K hrs. MIL-HDBK-217F(25℃) | ||
| Size | 40*125.2*113.5mm(W*H*D) | |||
| Packing | 0.6Kg; 20pcs/13Kg/1.16CUFT | |||
| Note |
1. Unless otherwise specified, all specification parameters are measured at an input of 230VAC, rated load, and an ambient temperature of 25 ℃. 2. Ripple and noise measurement method: Use a 12 "twisted pair cable, with terminals connected in parallel with 0.1uf and 47uf capacitors, and measure at a bandwidth of 20MHz. 3. Accuracy: including setting error, linear adjustment rate, and load adjustment rate. 4. The power supply should be considered as a part of the internal components of the system and should be confirmed for electromagnetic compatibility in conjunction with the terminal equipment. 5. Installation distance: When permanently loaded with full power, it is recommended to have a top distance of 40mm, a bottom distance of 20mm, and a distance of 5mm on both sides. If the adjacent device is a heat source, the recommended spatial distance is 15mm. 6. Under low input voltage, the output needs to be reduced. 7. When the altitude exceeds 2000 meters (6500 feet), the ambient temperature of the fanless model decreases proportionally every 3.5 ℃/1000m, while the ambient temperature of the fanned model decreases proportionally every 5 ℃/1000m. |
|||
Workshop Production Line

Production Line Setup

Assembly Process

Quality Inspection

Testing Stage

Packaging Area

Final Storage
Product Application

Communication Devices

Data Center

Industrial Automation

Lighting System

NC Machine

Rail Transit System

Traffic Light

Base Station

Mechanical Equipment
Frequently Asked Questions
What is the input voltage range for this power supply?
The NDR-120 series power supply features a universal AC input range from 90V to 264VAC, and it can also accept a DC input range of 127-370VDC by connecting AC/L (+) and AC/N (-).
What mounting configurations are supported?
It is designed for standard industrial setups and can be easily installed on TS-35/7.5 or TS-35/15 DIN rails.
What safety protections does the unit have?
The unit includes comprehensive protections against short circuits, overloads, overvoltages, and overtemperature conditions to ensure safe operation.
Does this power supply require external cooling fans?
No, it is designed to be cooled by free air convection. Make sure to follow the recommended installation distances of 40mm at the top, 20mm at the bottom, and 5mm on the sides for optimal airflow.
What is the warranty period for the NDR-120 power supply?
This product comes with a 3-year manufacturer warranty covering any defects in materials or workmanship under normal usage.