Leave Your Message
China NDR-120-24 Din Rail Switching Power Supply 24V 120W - Reliable Suppliers and Factory Solutions
Hot Products

China NDR-120-24 Din Rail Switching Power Supply 24V 120W - Reliable Suppliers and Factory Solutions

Our China-based factory specializes in high-quality Din rail power supplies designed for industrial automation and control systems. We offer a diverse range of series, including NDR, EDR, MDR, DR, and HDR, with output voltages from 5V to 48V. As trusted suppliers in the industry, we ensure that our products meet strict safety and quality standards, holding certifications such as European CE, RoHS, and FCC. Choose our reliable power supplies for optimal performance in your industrial applications
  • Model NDR-120-12
  • Models NDR-120-24
  • Models NDR-120-48

HXFeatures:

1
Universal AC input / full range: 90-264V
2
Short circuit / Overload / over Voltage / over temperature Protection
3
LED indicator for power on
4
Cooling by free air convection
5
Soft-start current, decrease AC Inrush current
6
Can be installed on DIN rail: TS-35/7.5 or TS-35/15
7
Installed with EMI filter, minimum wave
8
Small size & light weight
9
3 years warranty

HXSpecifications

Model NDR-120-12 NDR-120-24 NDR-120-48
Output DC voltage 12V 24V 48V
Rated current 10A 5A 2.5A
Current range 0~10A 0~5A 0~2.5A
Rated power 120W 120W 120W
Ripple and noise (maximum) 100mVp-p 120mVp-p 150mVp-p
Voltage adjustment range 12~14V 24~28V 48~55V
Voltage accuracy ±2.0% ±1.0% ±1.0%
Linear adjustment rate ±0.5% ±0.5% ±0.5%
Load adjustment rate ±1.0% ±1.0% ±1.0%
Start and rise time 1200ms,60ms/230VAC 2500ms,60ms/115VAC(full load)
Hold time (Typ.) 16ms/230VAC 10ms/115VAC(full load)
Input Voltage range 90-264VAC 127-370VDC [DC input can be achieved by connecting AC/L (+), AC/N (-)]
Frequency range 47~63Hz
Efficiency (Typ.) 85.50% 88% 89%
AC current (Typ.) 2.25A/115VAC 1.3A/230VAC
Surge current (Typ.) 20A/115VAC 35A/230VAC
Leakage current <1mA/240VAC
Protection Overload 105%~130% of rated output power
Protection mode: constant current mode, abnormal load bar
Overvoltage 14~17V 29~33V 56~65V
Protection mode: Turn off output, normal output can be restored after power restart
Over temperature Turn off output, normal output can be restored after power restart
Environment Working temperature -20~+70℃
Working humidity 20~95%RH,non-condensing
Storage temperature and humidity -40~+85℃,10~95%RH
Temperature coefficient ±0.03%/℃(0~50℃)
Vibration resistance Component: 10~500Hz, 2G10 minutes/cycle, X, Y, Z each for 60 minutes; Installation: Compliant with IEC60068-2-6
Safety regulations and electromagnetic compatibility Safety regulations UL508, EAC TP TC 004, TUV EN62368-1 certification passed; (Meets EN60204-1)
Voltage resistance I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC
Insulation impedance I/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC/25℃/70% RH
Electromagnetic compatibility emission Compliant with EN55032 (CISPR32), EN61204-3 CIass B,EN61000-3-2,-3,EAC TP TC 020
Electromagnetic compatibility immunity Complies with EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, A-grade heavy industry standard EAC TP TC 020
Other MTBF ≥456.3K hrs. MIL-HDBK-217F(25℃)
Size 40*125.2*113.5mm(W*H*D)
Packing 0.6Kg; 20pcs/13Kg/1.16CUFT
Note 1. Unless otherwise specified, all specification parameters are measured at an input of 230VAC, rated load, and an ambient temperature of 25 ℃.
2. Ripple and noise measurement method: Use a 12 "twisted pair cable, with terminals connected in parallel with 0.1uf and 47uf capacitors, and measure at a bandwidth of 20MHz.
3. Accuracy: including setting error, linear adjustment rate, and load adjustment rate.
4. The power supply should be considered as a part of the internal components of the system and should be confirmed for electromagnetic compatibility in conjunction with the terminal equipment.
5. Installation distance: When permanently loaded with full power, it is recommended to have a top distance of 40mm, a bottom distance of 20mm, and a distance of 5mm on both sides. If the adjacent device is a heat source, the recommended spatial distance is 15mm.
6. Under low input voltage, the output needs to be reduced
7. When the altitude exceeds 2000 meters (6500 feet), the ambient temperature of the fanless model decreases proportionally every 3.5 ℃/1000m, while the ambient temperature of the fanned model decreases proportionally every 5 ℃/1000m.

HXWorkshop Production Line

HXProduct Application

HXFrequently Asked Questions

What is the input voltage range for the NDR-120 series power supply?

The universal AC input voltage range is 90-264VAC, and it also supports DC input from 127-370VDC by connecting AC/L (+) and AC/N (-).

What protections are built into the NDR-120 DIN rail power supply?

It features short circuit, overload, over voltage, and over temperature protection to ensure safe operation. The overload protection uses a constant current mode.

Can the NDR-120 be mounted on standard DIN rails?

Yes, it is designed for easy installation on standard TS-35/7.5 or TS-35/15 DIN rails.

What are the output voltage options available for this series?

The NDR-120 series offers three output models: NDR-120-12 (12V, 10A), NDR-120-24 (24V, 5A), and NDR-120-48 (48V, 2.5A).

What is the recommended installation distance for optimal cooling?

For permanent full power load, it is recommended to keep a distance of 40mm at the top, 20mm at the bottom, and 5mm on both sides. If the adjacent device is a heat source, the recommended spatial distance is 15mm.

What is the warranty period for the NDR-120 series?

The NDR-120 series DIN rail power supplies come with a comprehensive 3-year warranty.