China 24V 800W Switch Mode Power Supply - High Efficiency AC to DC Converter from Reliable Suppliers and Factory
HX Features:
AC input wide range: 110/220V
OEM and ODM is welcome
Withstand 300VAC surge input for 5 seconds
Forced air cooling by built-in DC fan
High efficiency, long life and high reliability
100% full load aging test
Protections: Short circuit/ Overload/ Over voltage /Over temp.
2 years warranty
HX Specifications
| Datasheet: | |||
| MODEL | HX-800-24 | HX-800-36 | |
| OUTPUT | DC voltage | 24V | 36V |
| Rated current | 33.3A | 22.2A | |
| Current range | 0-33.3A | 0-22.2A | |
| Rated power | 800W | 800W | |
| Ripple & noise | 240mVp-p | 300mVp-p | |
| Voltage adj range | 20.8~26.5V | 33~39.6V | |
| Voltage tolerance | ±1% | ±1% | |
| Line regulation | ±0.5% | ±0.5% | |
| Load regulation | ±0.5% | ±0.5% | |
| Setup, rise time | 200ms, 100ms | ||
| Hold up time | 20ms | ||
| INPUT | Voltage range | 180-264VAC | |
| Frequency range | 47-63Hz | ||
| AC current | 4.5A/230VAC | ||
| Inrush current | 60A/230VAC | ||
| Efficiency | >86% | >88% | |
| Leakage current | <3.5mA/240VAC | ||
| PROTECTION | Overload | 115-130% rated output power | |
| Over voltage | 115%-150% of voltage | ||
| Protection type: shut down o/p voltage, re-power on to recover | |||
| Over temperature | -30°C ~ +60°C | ||
| Protection type: shut down o/p voltage, recover automatically after temperature goes down | |||
| ENVIRONMENT | Working temp. | -20°C ~ +50°C | |
| Working humidity | 20%~90%RH non-condensing | ||
| Storage temp. | -30°C ~ +85°C | ||
| Storage humidity | 10%~90%RH | ||
| TEMP coefficient | ±0.05%/°C (0-50°C) | ||
| SAFETY | Safety standards | Compliance to EN55022:2006+A1:2007; EN55024; EN 60950; EN61000-3-2:2006+A1:2009+A2:2009; EN61000-3-3:2008 | |
| Withstand voltage | I/P-O/P:1500VAC, I/P-FG:1500VAC, O/P-FG:500VAC | ||
| Isolation res. | I/P-O/P, I/P-FG, O/P-FG: 100MΩ | ||
| OTHERS | MTBF | 197K hrs min. MIL-HDBK-217F (25°C) | |
| Dimension | 240*125*65mm (L*W*H) | ||
| Packing | 1.40kg/pc, 10pcs/ctn | ||
| Certification | CE/FCC/RoHS | ||
NOTE:
- 1. All parameters NOT specially mentioned are measured at normal input, rated load and 25 °C of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance: includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
HX Size
HX Workshop Production Line
HX Frequently Asked Questions
What output models are available for the HX-800 power supply series?
The HX-800 series is available in two output models: the HX-800-24 (which provides a 24V DC output at a rated current of 33.3A) and the HX-800-36 (which provides a 36V DC output at a rated current of 22.2A).
What type of cooling system does the HX-800 power supply use?
This power supply is designed with a forced air cooling system powered by a built-in DC fan, ensuring stable heat dissipation during full-load operations.
What protections are built into this power supply?
The HX-800 features multiple safety protections, including short circuit protection, overload protection (115-130% rated output power), over voltage protection (115%-150% of voltage), and over temperature protection.
Can the output voltage of the HX-800 be adjusted?
Yes, the output voltage can be adjusted. The voltage adjustment range is 20.8V to 26.5V for the HX-800-24 model, and 33V to 39.6V for the HX-800-36 model.
What certifications and safety compliance does the HX-800 series hold?
The HX-800 series is certified with CE, FCC, and RoHS. It complies with safety standards including EN55022, EN55024, EN60950, EN61000-3-2, and EN61000-3-3.
What is the warranty period and reliability rating of the HX-800?
The power supply comes with a 2-year warranty and features a high MTBF (Mean Time Between Failures) rating of 197K hours minimum under MIL-HDBK-217F standards at 25°C.