Leave Your Message
24V 120W NDR-120-24 Din Rail Switching Power Supply | China Supplier & Factory for Industrial Automation
Hot Products

24V 120W NDR-120-24 Din Rail Switching Power Supply | China Supplier & Factory for Industrial Automation

Discover our high-quality Din rail power supplies, designed specifically for industrial automation and control systems. As a leading factory in China, we offer a diverse range of series including NDR, EDR, MDR, DR, and HDR, with output voltages varying from 5V to 48V. Our products are compliant with international standards, featuring certifications such as European CE, RoHS, and FCC. Partner with reliable suppliers for your power supply needs and ensure optimal performance in your automation applications.

  • Model NDR-120-12
  • Models NDR-120-24
  • Models NDR-120-48

HX Features

Universal AC input / full range: 90-264V
Short circuit / Overload / over Voltage / over temperature Protection
LED indicator for power on
Cooling by free air convection
Soft-start current, decrease AC Inrush current
Can be installed on DIN rail: TS-35/7.5 or TS-35/15
Installed with EMI filter, minimum wave
Small size & light weight
3 years warranty

HX Specifications

Model NDR-120-12 NDR-120-24 NDR-120-48
Output DC voltage 12V 24V 48V
Rated current 10A 5A 2.5A
Current range 0~10A 0~5A 0~2.5A
Rated power 120W 120W 120W
Ripple and noise (maximum) 100mVp-p 120mVp-p 150mVp-p
Voltage adjustment range 12~14V 24~28V 48~55V
Voltage accuracy ±2.0% ±1.0% ±1.0%
Linear adjustment rate ±0.5% ±0.5% ±0.5%
Load adjustment rate ±1.0% ±1.0% ±1.0%
Start and rise time 1200ms,60ms/230VAC 2500ms,60ms/115VAC(full load)
Hold time (Typ.) 16ms/230VAC 10ms/115VAC(full load)
Input Voltage range 90-264VAC 127-370VDC [DC input can be achieved by connecting AC/L (+), AC/N (-)]
Frequency range 47~63Hz
Efficiency (Typ.) 85.50% 88% 89%
AC current (Typ.) 2.25A/115VAC 1.3A/230VAC
Surge current (Typ.) 20A/115VAC 35A/230VAC
Leakage current <1mA/240VAC
Protection Overload 105%~130% of rated output power
Protection mode: constant current mode, abnormal load bar
Overvoltage 14~17V 29~33V 56~65V
Protection mode: Turn off output, normal output can be restored after power restart
Over temperature Turn off output, normal output can be restored after power restart
Environment Working temperature -20~+70℃
Working humidity 20~95%RH,non-condensing
Storage temperature and humidity -40~+85℃,10~95%RH
Temperature coefficient ±0.03%/℃(0~50℃)
Vibration resistance Component: 10~500Hz, 2G10 minutes/cycle, X, Y, Z each for 60 minutes; Installation: Compliant with IEC60068-2-6
Safety & EMC Safety regulations UL508, EAC TP TC 004, TUV EN62368-1 certification passed; (Meets EN60204-1)
Voltage resistance I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC
Insulation impedance I/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC/25℃/70% RH
EMC emission Compliant with EN55032 (CISPR32), EN61204-3 Class B,EN61000-3-2,-3,EAC TP TC 020
EMC immunity Complies with EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, A-grade heavy industry standard EAC TP TC 020
Other MTBF ≥456.3K hrs. MIL-HDBK-217F(25℃)
Size 40*125.2*113.5mm(W*H*D)
Packing 0.6Kg; 20pcs/13Kg/1.16CUFT
Note 1. Unless otherwise specified, all specification parameters are measured at an input of 230VAC, rated load, and an ambient temperature of 25 ℃.
2. Ripple and noise measurement method: Use a 12 "twisted pair cable, with terminals connected in parallel with 0.1uf and 47uf capacitors, and measure at a bandwidth of 20MHz.
3. Accuracy: including setting error, linear adjustment rate, and load adjustment rate.
4. The power supply should be considered as a part of the internal components of the system and should be confirmed for electromagnetic compatibility in conjunction with the terminal equipment.
5. Installation distance: When permanently loaded with full power, it is recommended to have a top distance of 40mm, a bottom distance of 20mm, and a distance of 5mm on both sides. If the adjacent device is a heat source, the recommended spatial distance is 15mm.
6. Under low input voltage, the output needs to be reduced.
7. When the altitude exceeds 2000 meters (6500 feet), the ambient temperature of the fanless model decreases proportionally every 3.5 ℃/1000m, while the ambient temperature of the fanned model decreases proportionally every 5 ℃/1000m.

HX Workshop Production Line

HX Product Application

Frequently Asked Questions

What is the input voltage range of the NDR-120 series power supply?
The NDR-120 series supports a universal AC input range from 90V to 264VAC, and a DC input range from 127V to 370VDC.
Can the output voltage be adjusted?
Yes. The voltage adjustment ranges are 12~14V for the NDR-120-12 model, 24~28V for the NDR-120-24 model, and 48~55V for the NDR-120-48 model.
What safety certifications does this power supply have?
The NDR-120 series power supply has passed UL508, EAC TP TC 004, and TUV EN62368-1 certifications, meeting EN60204-1 safety standards.
How is the power supply cooled?
It features cooling by free air convection, which allows it to operate without a fan within a working temperature range of -20℃ to +70℃.
What type of DIN rail is suitable for installation?
It is designed for standard DIN rail mounting and can be easily installed on TS-35/7.5 or TS-35/15 rails.
What is the warranty period?
The product comes with a comprehensive 3-year warranty from the date of purchase.