DC 60V 10A 600W High quality Switching power supply
HXFeatures:
2.Withstand 300VAC surge inpupt for 5 seconds
3.Forced air cooling by built-in DC fan
4.High efficiency, long life and high reliability
5.100% full load aging test
6.Protections: Short circuit/ Overload/ Over voltage /Over temperature
7.2 years warranty
8.OEM & ODM is welcome
HXSpecifications
MODEL |
HX-600-12 |
HX-600-60 |
|
OUTPUT |
DC voltage |
12V |
60V |
Rated current |
50A |
10A |
|
Current range |
0-50A |
0-10A |
|
Rated power |
600W |
600W |
|
Ripple&noise |
<120mVp-p |
<450mVp-p |
|
Voltage adj range |
±10% |
±10% |
|
Voltage tolerance |
±1% |
±1% |
|
Line regulation |
±0.5% |
±0.5% |
|
Load regulation |
±0.5% |
±0.5% |
|
Setup,rise time |
200ms,100ms |
||
Hold up time |
20ms |
||
INPUT |
Voltage range |
90-132VAC / 180-264VAC Selected by switch |
|
Frequency range |
47-63Hz |
||
AC current |
4.5A/115VAC 2.5A/230VAC |
||
Inrush current |
25A/115VAC 50A/230VAC |
||
Efficiency |
82% |
86% |
|
Leakage current |
<3.5mA/240VAC |
||
PROTECTION |
Overload |
105-125% rated output power |
|
Over voltage |
115%-150% of voltage |
||
Protection type: shut down o/p voltage, re-power on to recover |
|||
Over temperature |
-10°C ~ +60°C |
||
Protection type: shut down o/p voltage, recover automatically after temperature goes down |
|||
ENVIRONMENT |
Working temperature |
80°C±5°C |
|
Working humidity |
20%~90%RH non-condensing |
||
Storage temperature |
-10°C ~ +60°C |
||
Storage humidity |
10%~90%RH |
||
TEMP coefficient |
±0.05%/°C (0-50°C) |
||
SAFETY |
Safety standards |
Compliance to EN55022:2006+A1:2007; EN55024; EN 60950 EN61000-3-2:2006+A1:2009+A2:2009; EN61000-3-3:2008 |
|
Withstand voltage |
I/P-O/P:1500VAC, I/P-FG:1500VAC, O/P-FG:500VAC |
||
Isolation resistance |
I/P-O/P,I/P-FG,O/P-FG: 100MΩ |
||
OTHERS |
MTBF |
197K hrs min. MIL-HDBK-217F (25°C) |
|
Dimension |
215*115*50mm (L*W*H) |
||
Packing |
0.93kg/pc, 10pcs/ctn |
||
NOTE |
1. All parameters NOT specially mentioned are measured at normal input, rated load and 25 °C of ambient temperature. |
||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. |
|||
3. Tolerance : includes set up tolerance, line regulation and load regulation. |
|||
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
HXproduct size