Leave Your Message
3000W 60V Switching power supply

Switching Power Supply

3000W 60V Switching power supply

This is a power supply especially used for different devices with features of adjusting output voltage and current, current equalization, remote on/off control, 485 communication control, and auxiliary power supply provide design flexibility. It adopts an efficient distillation circuit, greatly improving efficiency, with an efficiency of over 85% to 93%, the DC output can be 5V~1000V. Our power supplies have the certifications of European CE, RoHS, FCC, etc.

  • Model HX-3000-24
  • Models HX-3000-36
  • Models HX-3000-48
  • Models HXX-3000-120
  • Models HX-3000-220

HXFeatures:

1.AC input range selected by switch
2.OEM and ODM is welcome
3.Withstand 300VAC surge inpupt for 5 seconds
4.Forced air cooling by built-in DC fan
5.High efficiency, long life and high reliability
6.100% full load aging test
7.Protections: Short circuit/ Overload/ Over voltage /Over temperature
8.2 years warranty

HXSpecifications

Models

HX-3000-24

HX-3000-36

HX-3000-48

HXX-3000-120

HX-3000-220

Output

DC Voltage

24V

36V

48V

120V

220V

Rated Current

125A

83.3A

62.5A

25A

13.6A

Current Range

0-125A

0-83.3A

0-62.5A

0-25A

0-13.6A

Rated Power

3000W

Ripple

200mV

260mV

300mV

850mV

1000mV

Constant Current Range

12-24V

18-36V

24-48V

60-120V

110-220V

Voltage Accuracy

士1.0%

Linear Adjustment Ratio

士1.0%

Load Adjustment Rate

士1.0%

Startup & Rise Time

1500mS, 100mS/230VAC(full load)

Input

Voltage Range

90-190VAC (50% of output current),190-275VAC (100% of output current)

Frequency Range

47Hz - 63Hz

Power Factor

PF≧0.99/230VAC(Full load)

Efficiency

90%

92%

92.50%

93%

93%

AC Current

<17.5A

Leakage Current

<3.0mA / 240VAC

Protection

Short Circuit

Shutdown and lockout of output voltage, restored after restarting

Over Current

User settable overcurrent value delays output for 5 seconds, restored after reboot

Over Voltage

User can set the overvoltage value to turn off the output voltage, recover after reboot

Over Temperature

Turn off the output, recover automatically after temperature drop or restart recovery

Functions

Output Voltage Adjustment

0 - 24V

0-36V

0-48V

0-120V

0-220V

Output Constant Current Adjustment

0-125A

0-83.3A

0-62.5A

0-25A

0-13.6A

Average Current

Parallel Flow Averaging

Auxiliary Power

12V 0.5A

Alarm Signal Output

Power normal signal (dry contact≦30V,0.1A)

Environment

Work Temperature

-20±65℃

Working Humidity

-20 - 90%RH non condensing

Storage Temperature and Humidity

-40 - +85℃, 10 - 95%RH non condensing

Vibration Resistant

10-500Hz, 2G 10 minutes/cycle, 60 minutes each for X, Y, and Z axes

Safety

Insulation impedance

Input to Output:100Mhms/500VDC/25℃/70%RH

pressure resistance

I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

EMC Emission

GB 9254 Class A

EMC immunity

GB 9254 Class A

Other

Dimension

288*67*157mm(L*W*H)

Net weight

3.5KG

Note

1. All parameters are measured at 230VAC input voltage, rated load and 25°C when not otherwise specified. 2. Ripple and noise voltages are measured at 20 MHz bandwidth oscilloscope with 12-inch twisted-pair cable terminated with 0.1μ and 47μ capacitors, measured at 20 MHz bandwidth. Measured at 20MHZ bandwidth. 3. Accuracy: Includes setup error, linearity and load regulation. 4. Low input voltage requires output derating, please refer to the static characteristics graph for details. 5. Start-up time is measured under cold start-up, frequent switching may increase the start-up time.

 

HXWorkshop Production Line

Workshop Production Line2fyf
Workshop Production Line3cce
Workshop Production Line4vtt
Workshop Production Line5er7
Workshop Production Line73ee
Workshop Production Line837p

HXProduct Application

communication devices
Data center
Industrial Automation
Lighting System
nc machine
rail transit system
Traffic light
Base station