3000W 60V Switching power supply
HXFeatures:
2.OEM and ODM is welcome
3.Withstand 300VAC surge inpupt for 5 seconds
4.Forced air cooling by built-in DC fan
5.High efficiency, long life and high reliability
6.100% full load aging test
7.Protections: Short circuit/ Overload/ Over voltage /Over temperature
8.2 years warranty
HXSpecifications
Models |
HX-3000-24 |
HX-3000-36 |
HX-3000-48 |
HXX-3000-120 |
HX-3000-220 |
|
Output |
DC Voltage |
24V |
36V |
48V |
120V |
220V |
Rated Current |
125A |
83.3A |
62.5A |
25A |
13.6A |
|
Current Range |
0-125A |
0-83.3A |
0-62.5A |
0-25A |
0-13.6A |
|
Rated Power |
3000W |
|||||
Ripple |
200mV |
260mV |
300mV |
850mV |
1000mV |
|
Constant Current Range |
12-24V |
18-36V |
24-48V |
60-120V |
110-220V |
|
Voltage Accuracy |
士1.0% |
|||||
Linear Adjustment Ratio |
士1.0% |
|||||
Load Adjustment Rate |
士1.0% |
|||||
Startup & Rise Time |
1500mS, 100mS/230VAC(full load) |
|||||
Input |
Voltage Range |
90-190VAC (50% of output current),190-275VAC (100% of output current) |
||||
Frequency Range |
47Hz - 63Hz |
|||||
Power Factor |
PF≧0.99/230VAC(Full load) |
|||||
Efficiency |
90% |
92% |
92.50% |
93% |
93% |
|
AC Current |
<17.5A |
|||||
Leakage Current |
<3.0mA / 240VAC |
|||||
Protection |
Short Circuit |
Shutdown and lockout of output voltage, restored after restarting |
||||
Over Current |
User settable overcurrent value delays output for 5 seconds, restored after reboot |
|||||
Over Voltage |
User can set the overvoltage value to turn off the output voltage, recover after reboot |
|||||
Over Temperature |
Turn off the output, recover automatically after temperature drop or restart recovery |
|||||
Functions |
Output Voltage Adjustment |
0 - 24V |
0-36V |
0-48V |
0-120V |
0-220V |
Output Constant Current Adjustment |
0-125A |
0-83.3A |
0-62.5A |
0-25A |
0-13.6A |
|
Average Current |
Parallel Flow Averaging |
|||||
Auxiliary Power |
12V 0.5A |
|||||
Alarm Signal Output |
Power normal signal (dry contact≦30V,0.1A) |
|||||
Environment |
Work Temperature |
-20±65℃ |
||||
Working Humidity |
-20 - 90%RH non condensing |
|||||
Storage Temperature and Humidity |
-40 - +85℃, 10 - 95%RH non condensing |
|||||
Vibration Resistant |
10-500Hz, 2G 10 minutes/cycle, 60 minutes each for X, Y, and Z axes |
|||||
Safety |
Insulation impedance |
Input to Output:100Mhms/500VDC/25℃/70%RH |
||||
pressure resistance |
I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
|||||
EMC Emission |
GB 9254 Class A |
|||||
EMC immunity |
GB 9254 Class A |
|||||
Other |
Dimension |
288*67*157mm(L*W*H) |
||||
Net weight |
3.5KG |
|||||
Note |
1. All parameters are measured at 230VAC input voltage, rated load and 25°C when not otherwise specified. 2. Ripple and noise voltages are measured at 20 MHz bandwidth oscilloscope with 12-inch twisted-pair cable terminated with 0.1μ and 47μ capacitors, measured at 20 MHz bandwidth. Measured at 20MHZ bandwidth. 3. Accuracy: Includes setup error, linearity and load regulation. 4. Low input voltage requires output derating, please refer to the static characteristics graph for details. 5. Start-up time is measured under cold start-up, frequent switching may increase the start-up time. |
HXWorkshop Production Line






HXProduct Application









description2